Malad West, Mumbai, Maharashtra
Leading Manufacturers, Exporters, Wholesaler, Distributor and Importer of Digital Microprocessor Based Automatic Karl Fischer Titration Apparatus and Digital Microprocessor Based Automatic Karl Fischer Titrator from Mumbai.
Business Type | Manufacturer, Exporter, Supplier, Distributor, Importer |
Model | KFT 630 |
Make | Prolab India |
Titrator Type | Automatic |
Titration Method | Volumetric |
Measuring Range | 50ppm to 999999ppm, 0% to 100% of moisture |
Measuring Method | Volumetric |
K.F. Dispensing System | Highly sensitive motorized dispensing system |
Resolution of Titrant Volume | 0.01 ml |
Indication of Titrant Volume | 0.00 to 99.99 ml |
Auto Moisture content Calculation | 0.00% to 100%, 50 ppm to 999999 ppm |
Calibration | Auto K.F. Titer/Factor calculation |
End Point Indication | Audio |
Utilization Environmental Temperature | 5-40°C, Humidity: ≤85% |
Wait Time for End Point | Adjustable 1 to 99 seconds |
Keypad | 20 Keys |
Display | 128x64 Graphical LCD |
Data Storage | 1000 Sample |
PC connection compatibility | USB Hyper terminal |
Clock | In Built Clock with Date & Time Display |
Stirrer | In Built Magnetic Stirrer with Adjustable Speed |
Reagent Bottles | 250 Ml Bottles of Kf Reagent, Methanol & Calcium Chloride |
Printer Interface | Dot Matrix Printer Interface |
Power Supply | 12V/2A DC Supply |
Preferred Buyer From
Location | Worldwide |
FEATURES:
Accessories: Dual Platinum Electrode, Teflon Coated Magnetic Stirring Capsule, 250ml Bottle for K.F Reagent, Methanol, Calcium Chloride, Reagent Outer, 25µl Auto Pipette, Adapter for Calcium Chloride Bottle, Adaptor for K.F. Reagent Bottle, Set of connecting tubes, Titration Vessel, Set of Dispensing tubes & nozzels, Power Supply Adaptor, Rubber Bellow, Instruction Manual, Dust Cover.
Business Type | Manufacturer, Exporter, Supplier, Distributor, Importer |
Make | Prolab India |
Model | 1760 |
Titrator Type | Automatic |
Titration Method | Volumetric |
Measuring Range | 100ppm to 100% of moisture |
Measuring Method | Karl Fischer Volumetric Titration method. |
K.F. Dispensing | Highly sensitive motorized dispensing system. |
Resolution of Titrant Volume | 0.01 ml |
Indication of Titrant Volume | 0.00 to 99.99 ml on display |
Moisture content calculation (Automatic) | %age : (0.00 to 100%), ppm :: (100 to 999999), mg H2O : (0.00 to 999.99) |
Kf Titer Factor | In-built Automatic Kf Titer Factor Calculation Facility |
End Point Alarm | Visual LED and Audible Alarm |
Dispensing Pump Calibration | Available through Keyboard |
Wait Time for End Point | Adjustable (1 to 59 seconds) |
Key Board | 24 Keys Soft Touch Membrane Type |
Sample Storage | Upto 20 Latest Samples Using Fifo Memory |
Display | 8 Digit Bright Red Seven Segment Display |
Clock | In-built Clock with Date & Time Display |
Stirrer | In-built Magnetic Stirrer with Adjustable Speed |
Reagent Bottle | 3x250ml bottle for KF Reagent, methanol & calcium chloride |
Printer Interface | External Serial Printer Interface Available |
Power Supply | 230V A.C ± 10% 50 Hz |
Dimensions | 360 x 295 x 175 mm |
Preferred Buyer From
Location | Worldwide |
Microprocessor KF Moisture Titrator – 1760 is the finest volumetric titrator available. It uses the latest microcontroller technology and advanced engineering techniques so as to give enhanced accuracy and reproducibility. The system has user friendly prompts which guide you throughout the titration process. This titrator eliminates the use of conventional delicate and fragile glass burettes and plunger systems. It uses a highly sensitive motorized dispensing system for precise control of titrant volumes. This titrator analyses the moisture concentration of liquid samples, powder, fine particles and fiber samples that are soluble in alcohol or solvents. The moisture content is displayed in ppm, %age and mg H2O.
The system has 24 soft touch membrane type keys for ease of operation. Complete numeric keypad is provided so as to feed the values of sample, density, titer factor, date, time etc. comfortable. The End Point indication is given by both visual LED and audible alarm. The titrator has the facility for automatically calculating the titer factor of the Karl Fischer reagent. It uses the repeated averaging method so as to give the most accurate titer value. It has the storage facility of date, time, batch no. and final results of 20 titrations using the FIFO method. The internal battery backup provision has been made to store the results and the other titration parameters for a minimum of 1 month even if the instrument is not switched ON. Provision for external printer attachment is available so that any of the stored results can be printed even at a later stage.
Accessories: Dual Platinum Electrode, Built-In Magnetic Stirrer, 250ml Bottle for Methanol, 10 Syringe, Adapter for KF Reservoir, Set of Dispenser Tubes, Bottle Container, Dust Cover, Titration Vessel with Teflon Cover, Teflon Coated Magnetic Stirring Capsule, 250 ml Reservoir Bottle for KF Solution, 250 ml bottle for Calcium Chloride, Adapter for Methanol Reservoir Bottle, Set of Connecting Tubes, Main Lead, Instruction Manual
FEATURES:
Hi! Simply click below and type your query.
Our experts will reply you very soon.