Double Beam UV Visible Spectrophotometer with PC Controlled Software

Business Type Manufacturer, Exporter, Supplier, Distributor, Importer
Model UV-2704
Make Prolab India
Wavelength Range 190-1100nm
Click to view more

Preferred Buyer From

Location Worldwide

Product Details

Spectral Bandwidth
1nm
Optical System
Double Beam, Blazed Holographic Grating (1200 lines/mm)
Wavelength Accuracy
±0.5nm
Wavelength Repeatability
≤0.2nm
Wavelength Setting
Auto, Resolution 0.1nm
Photometric Range
0~200%T, -4~4A, 0~9999C
Photometric Accuracy
±0.002 A (0~0.5A), ±0.003A (0.5~1A), ±0.3%T (0~100%T)
Photometric Repeatability
≤0.001 A (0~0.5A), ≤0.002A (0.5~1A), ≤0.2%T (0~100%T)
Stray Light
≤0.05%T(220/360nm)
Scan Speed
High, Medium, Low. Max.3200 nm/minute
Baseline Flatness
±0.0015A
Stability
±0.001A/h (500nm,0A)
Noise
≤0.2%T/3min (250/500nm,0%T); ≤0.5%T/3min (250/500nm,100%T)
Sample Compartment
10mm Pathlength Cuvette
Detector
Silicon Photodiode
Lamps
Tungsten Lamp & Deuterium Lamp (Pre-aligned)
Display
Graphic LCD (320*240 Dots)
Keypad
30-key Alphanumeric Membrance Keypad
Output Port
USB Port
Printer
Mini Serial Printer; PC Printer
PC Software
UV Analyst Scanning Software
Power Requirements
AC 90-250V, 50/60Hz
Dimension
545x468x245mm
Weight
18kg

FEATURES:

  • Double beam optical system
  • Low noise and Low stray light
  • Large LCD display, can display curve
  • High quality grating, detector and lamps
  • Data and Curve can be stored in real-time
  • Auto setting WL, auto Blank
  • Lamps can be turned on/off individually
  • Easy to change Pri-aligned lamps
  • Reinforced baseboard and bracket assures durability

 

FUNCTIONS: 

  • Photometric: T%, Abs
  • Quantitative: Standard Curve
  • System Utility
  • WL Scan (Spectrum Scan)
  • Time Scan (Kinetics)
  • DNA/Protein Test

Yes! I am interested


Basic Mode

Basic Mode

To measure the Absorbance and transmittance


Quantitative

Quantitative
  • Coefficient Method
  • Standard Curve Up to 10 Standard sample may be used to establish a curve. Four methods for fitting a curve through the calibration points : Linear fit. Linear fit through zero, Square fit and cubic fit

DNA/Protein Test

DNA/Protein Test

Concentration and DNA purity are quickly and easily calculated: Absorbance rations: 260 nm / 280 nm with optional subtracted absorbance at 320 nm. DNA concentration = 62.9XA260-36.0XA280 Protein concentration = 1552xA260-757.3xA 280


Wavelength Scan

Wavelength Scan
  • The wavelength scan intervals are 0.1,0.2,0.5,1,2,5 nm
  • High, Medium and low scan speed are available. They vary from 100 to 3600 nm/min
  • Wavelength are scanned from high to low so that the instrument waits at high WL. And it minimizes the degradation of UV sensitive samples.

Kinetics

Kinetics

Abs vs time graphs is displayed on the screen in real-time wait time and measurement time up to 12 hours may be entered with time interval of 0.5,1,2,5,10,30 seconds and one min. Post-run manipulation includes re-scaling, curve tracking and selection of the part of the curve required for rate calculation. Rate is calculated using a linear regression algorithm before multiplying be the entered factor.


Looking for "Double Beam UV Visible Spectrophotometer with PC Controlled Software" ?


Close

Raise your Query

Hi! Simply click below and type your query.

Our experts will reply you very soon.

WhatsApp Us